Balancing Transmittance, Anti-Soiling and Weathering in a Dual-Layer AR Coating for PV Glass

ConvSun's CG-108H dual-layer AR coating for photovoltaic cover glass is now in industrial production. The design problem is not how to raise transmittance alone, but how to hold that gain in the field.

The front glass of a photovoltaic module is an optical surface that has to work outdoors for the life of the module. An anti-reflective (AR) coating is there to cut reflection at the glass–air interface and let more of the solar spectrum reach the cells. Raising transmittance is only useful if the film still resists soiling and holds its optical and mechanical properties through heat, humidity, abrasion and cleaning. Those three demands pull against each other. A coat designed for peak laboratory transmittance can lose that gain once pores take up water or soils fill the surface; a coat designed only for hardness or a closed surface can give away the optical benefit that justified it.

At Convsun (Changzhou) New Materials Science and Technology Co., Ltd., we treat that tension as the starting point for the CG-108H dual-layer AR coating, which is now in industrial production.

Why a single porous film is a compromise

A practical AR coat on soda-lime solar glass is usually a porous silica film. Dense silica has a higher refractive index than the optical optimum for a quarter-wave layer on glass, so porosity is introduced to lower the effective index and reduce front-surface reflection. In effective-medium terms, more air in the film means a lower index and higher transmittance — up to the point at which the network is no longer a coherent film.

That is the first trade-off. As porosity rises, the solid skeleton that carries mechanical load becomes thinner. The film is more easily marked by cleaning and sand, and more open to humidity. Water that condenses in the pores has a much higher index than air, so the effective index of the wet film moves back towards that of the solid, and the optical gain shrinks. Prolonged moisture uptake also opens a path for hydrolysis and ion transport that can roughen or dissolve the network over time. The same structural feature that delivers transmittance is the one that undermines weathering and abrasion resistance.

Surface energy, pore size, soiling and water

Porosity is not the only variable, and bulk pore volume is not the same as the surface the environment actually sees. Pore size, and whether those pores are open at the surface, govern capillary condensation and the tendency of particulates to lodge in the film. Coarse or surface-open pores take up water readily and can trap soils, which both stain the glass and permanently raise the effective index. Tightening or closing the surface reduces uptake, but if that is done by simply densifying the whole film, the refractive index rises and transmittance is lost.

Surface energy sits on top of that structure. It controls wetting, how dew and rain move, and how readily dust and organic films adhere. A surface that holds a water film keeps soils in contact with the coat; one poorly matched to the climate can pin droplets or let dry soiling accumulate. Anti-soiling is therefore not a separate add-on chemistry. It is coupled to pore architecture and to the mechanical integrity of the outer surface: a film that is easily abraded will also lose the surface energy designed into it.

Decoupling the requirements in a dual-layer stack

In a single-layer coat, one film has to provide the low effective index, the mechanical network, the pore architecture and the surface chemistry. Those jobs conflict. A dual-layer stack is a way of assigning them to different parts of the film.

The inner layer can be formulated for adhesion to the glass and for the optical transition into the stack. The outer layer can then carry the high-transmittance function, while its surface chemistry and pore structure are designed to set surface energy, limit water uptake and soiling, and take mechanical wear — without forcing the entire thickness to the same density. The chemistry of each layer, and the interface between them, has to be compatible with a production coater and with the tempering cycle, so that the stack remains a fully inorganic film in service.

That separation is the point of the work: weathering and anti-soiling cannot be ignored in favour of transmittance, or the reverse, but the two functions no longer have to be optimised in the same material at the same porosity.

The two layers are shown in the SEM below.

Cross-section scanning electron micrograph of the CG-108H dual-layer anti-reflective coating, with the two layer thicknesses marked.
Cross-section SEM of the CG-108H dual-layer AR coating (layer thicknesses shown)

What the optical gain means in practice

The chemistry of this dual-layer stack gives about 0.5 percentage points higher transmittance than a standard single-layer AR coating. On a typical 700 W module, that is roughly 3.5 W more. That gain is only of use if it is still there after humidity, soiling and cleaning, so the stack is designed as a balance rather than a laboratory maximum.

The coating has been evaluated for abrasion, aqueous and acid immersion, damp heat, thermal cycling, humidity-freeze, salt mist, ultraviolet exposure and thermal shock, under the methods set out in JC/T 2170-2013 (2017) and IEC 61215. Test data and full conditions are available on request.

From formulation to the coating line

Both layers are designed for a standard roll coater and a standard oven, then tempered with the glass. We work from the glass, the coater and the tempering cycle, and qualify the stack as a system on the customer's glass where needed.

Photovoltaic cover glass being roll-coated with an anti-reflective coating on an industrial line.

Technical data sheets, test reports and samples are available on request.

If you are reviewing an AR coat for photovoltaic glass, we would be glad to talk.

Contact: xlw@convsun.cn | www.convsun.cn
Convsun (Changzhou) New Materials Science and Technology Co., Ltd., Changzhou, Jiangsu, China